{"id":789,"date":"2024-07-09T13:35:27","date_gmt":"2024-07-09T10:35:27","guid":{"rendered":"https:\/\/gazolcum.com\/?p=789"},"modified":"2024-07-10T12:58:15","modified_gmt":"2024-07-10T09:58:15","slug":"kkd-sinif-3un-kategori-3-denetimi-ve-bakimi","status":"publish","type":"post","link":"https:\/\/gazolcum.com\/en\/kkd-sinif-3un-kategori-3-denetimi-ve-bakimi\/","title":{"rendered":"Inspection and Maintenance of PPE Class 3 (Category 3)"},"content":{"rendered":"<div class=\"pagebuilder-column-group mf-initial\" data-content-type=\"column-group\" data-grid-size=\"12\" data-element=\"main\" data-was-processed=\"true\">\n<div class=\"pagebuilder-column mf-initial\" data-content-type=\"column\" data-appearance=\"full-height\" data-background-images=\"{}\" data-element=\"main\" data-pb-style=\"HHCEOLJ\" data-was-processed=\"true\">\n<div class=\"mf-initial\" data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p><strong>PPE class 3<\/strong>\u00a0(or category 3),\u00a0<strong>serious or fatal risks<\/strong>\u00a0providing protection against\u00a0<strong>corresponds to personal protective equipment. For obvious reasons related to worker safety, inspection, periodic verification and maintenance of such protection is essential and mandatory in most industrialized countries. These controls\u00a0<\/strong><strong>respiratory protective equipment<\/strong>\u00a0,\u00a0<strong>chemical protective clothing<\/strong>\u00a0And\u00a0<strong>fall protection<\/strong>\u00a0Includes\u00a0.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"main-title mf-initial\" data-was-processed=\"true\">\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Maintenance of respiratory protective equipment<\/h2>\n<div class=\"mf-initial\" data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p><strong>Respiratory protective equipment<\/strong>\u00a0(gas masks, powered air-purifying respirators, supplied-air respirator systems, self-contained breathing apparatus, etc.) are class 3 PPE. It must be inspected before each use and checked annually (mandatory) in accordance with standards and regulations for respiratory equipment.<br \/>\nOur laboratory has all the necessary equipment for cleaning and checking respiratory protection equipment: washing machines for washing and disinfecting masks and harnesses, drying cabinets, breathing air compressor with air quality analysis, inspection bench (Dr\u00e4ger Quaestor), for periodic inspections of compressed air cylinders Bagging machine to pack endoscope and clean and checked masks.<\/p>\n<div class=\"mf-initial\" data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>All\u00a0compressed air cylinders inflated in the workshop are inspected. Their filling is passed through an air quality analysis chamber according to the\u00a0EN12021 standard\u00a0(CO, CO2, O2, hygrometer, oil mist and dust control). After each inflation, a certificate of analysis of the quality of the inspired air is delivered.<\/p>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Maintenance of chemical protective clothing<\/h2>\n<div class=\"mf-initial\" data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>Reusable or limited use\u00a0<strong>chemical protective clothing\u00a0<\/strong><strong>category 3 personal protective equipment<\/strong>\u00a0(Considered PPE class 3). They are subject to a full inspection and an annual periodic check for ten years, which includes leakage testing of the suit and valves on the inspection bench (Quaestor).<\/p>\n<div class=\"mf-initial\" data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>GTC Industrial \u2013 an approved and authorized maintenance center \u2013 carries out annual periodic inspections of the entire Dr\u00e4ger and RSG chemical suit range in our maintenance laboratory. Feel free to contact us for this special class 3 PPE maintenance.<\/p>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Periodic inspection of fall protection equipment<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>Fall protection equipment\u00a0(safety belts, fall arresters, belt or cable self-retracting retractors, safety tripods, etc.) is class 3 PPE.\u00a0In accordance with standards and regulations regarding fall protection\u00a0<strong>should be inspected before each use<\/strong>\u00a0and periodically\u00a0(mandatory) in an approved care centre.\u00a0<strong>control<\/strong>\u00a0should be .<\/p>\n<p>Our authorized maintenance center takes into account various compatibility criteria, such as the proper functioning of the equipment, its general condition, the readability of the marking and the expiration date of the product. Storage conditions are also checked.<\/p>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Monitoring the maintenance of Class 3 PPE<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>Our simple, innovative and free GTC Industrial solution allows you to monitor, schedule and schedule periodic checks and maintenance of your class 3 PPE. Ideal for HSE managers and Service managers, GTC Industrial \u2013 GTC Industrial's intranet \u2013 offers the ability to view all current devices and equipment in your fleet and those that need to be returned for inspection or on-site intervention.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>KKD s\u0131n\u0131f 3\u00a0(veya kategori 3),\u00a0ciddi veya \u00f6l\u00fcmc\u00fcl risklere\u00a0kar\u015f\u0131 koruma sa\u011flayan\u00a0ki\u015fisel koruyucu ekipmana kar\u015f\u0131l\u0131k gelir. \u00c7al\u0131\u015fan g\u00fcvenli\u011fiyle ilgili bariz nedenlerden dolay\u0131, bu t\u00fcr koruman\u0131n denetimi, periyodik do\u011frulamas\u0131 ve bak\u0131m\u0131 \u00e7o\u011fu sanayile\u015fmi\u015f \u00fclkede elzem ve zorunludur. Bu kontroller\u00a0solunum koruyucu ekipman\u00a0,\u00a0kimyasal koruyucu giysi\u00a0ve\u00a0d\u00fc\u015fme korumas\u0131n\u0131\u00a0i\u00e7erir\u00a0. Solunum koruyucu ekipmanlar\u0131n bak\u0131m\u0131 Solunum koruyucu ekipmanlar\u00a0(\u00a0gaz maskeleri\u00a0,\u00a0motorlu hava temizleme respirat\u00f6rleri\u00a0,\u00a0hava beslemeli respirat\u00f6r sistemleri\u00a0,\u00a0ba\u011f\u0131ms\u0131z [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[37,38],"tags":[],"class_list":["post-789","post","type-post","status-publish","format-standard","hentry","category-hizmetler","category-servis-merkezi"],"_links":{"self":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts\/789","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/comments?post=789"}],"version-history":[{"count":2,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts\/789\/revisions"}],"predecessor-version":[{"id":1110,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts\/789\/revisions\/1110"}],"wp:attachment":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/media?parent=789"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/categories?post=789"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/tags?post=789"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}