{"id":804,"date":"2024-07-09T13:46:32","date_gmt":"2024-07-09T10:46:32","guid":{"rendered":"https:\/\/gazolcum.com\/?p=804"},"modified":"2024-07-10T12:51:53","modified_gmt":"2024-07-10T09:51:53","slug":"gaz-maskesi-solunum-korumanizi-nasil-secersiniz","status":"publish","type":"post","link":"https:\/\/gazolcum.com\/en\/gaz-maskesi-solunum-korumanizi-nasil-secersiniz\/","title":{"rendered":"Gas Mask \u2013 How to Choose Your Respiratory Protection"},"content":{"rendered":"<div class=\"pagebuilder-column-group mf-initial\" data-content-type=\"column-group\" data-grid-size=\"12\" data-element=\"main\" data-was-processed=\"true\">\n<div class=\"pagebuilder-column mf-initial\" data-content-type=\"column\" data-appearance=\"full-height\" data-background-images=\"{}\" data-element=\"main\" data-pb-style=\"L1QTF8N\" data-was-processed=\"true\">\n<div class=\"mf-initial\" data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>Gas\u00a0<strong>mask,\u00a0<\/strong><strong>half mask<\/strong>\u00a0and EN140 standard for\u00a0<strong>full face mask<\/strong>\u00a0It is a personal protective equipment (PPE class 3) subject to the EN136 standard for The most popular models have 40mm universal filters,\u00a0mainly due to the wide range of filters available\u00a0<strong>They are single cartridge DIN Rd40 versions (standard EN148-1).\u00a0<\/strong><strong>Double filter models,<\/strong>\u00a0They are more compact, have a wider field of view and better load balance than those designed for routine applications or meticulous work.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"main-title mf-initial\" data-was-processed=\"true\">\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Half mask<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>It only covers the lower part of the face (nose and mouth). It consists of a flexible seal and clamps to ensure a tight seal of the airways once set. However, there are two main restrictions on its use:<\/p>\n<ul>\n<li>The substances to be filtered are chlorine, ammonia and its derivatives or nitric acid, sulfuric acid, hydrochloric acid etc.\u00a0It should not be irritating to the eyes.<\/li>\n<li>Respiratory protection filters\u00a0must not exceed 300 grams in weight, which significantly limits combined gas and particle configurations, such as the ABEK2-P3 cartridges most commonly used in the industry, weighing in excess of 300 grams.<\/li>\n<\/ul>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Full face mask<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>It covers the entire face, nose, mouth and eyes. It is particularly suitable for use in environments that are highly toxic, corrosive or potentially hazardous to the mucous membranes of the eyes.<\/p>\n<p>It has five attachment points for fixing to the face and can support filter cartridges weighing more than 300 grams (and are therefore more effective because they have more filtering elements), such as REACTOR\u00a0filters\u00a0(radioactive iodine) A2B2E2K1-P3 Reactor or\u00a0CO\/NO filters\u00a0ABEK2HgNOCO20-P3 .<\/p>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Single cartridge RD DIN 40 gas mask or double cartridge gas mask?<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>There are two main categories: single-cartridge masks equipped with RD DIN 40 filters (40 mm universal standard thread) and double-cartridge masks, which are more compact, have a wide field of view and have better load balance.<\/p>\n<p><strong>rd40 masks<\/strong>\u00a0It has a wide range of filters (EN148-1 compliant). Due to their universality \u2013 all major brands of respiratory protection equipment offer RD DIN 40 filters \u2013 a wide range of filter cartridges are available.<\/p>\n<p><strong>Double cartridge masks<\/strong>\u00a0It has two side filters. These dual-filter devices have several attractive advantages: an excellent load balance (loads are better shared) and a wider field of view because the filters are positioned laterally on the side of the face.<\/p>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Respiratory protection mask use limits<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>Filtered respiratory protection devices should not be used in the following situations:<\/p>\n<ul>\n<li>When the oxygen level in the air is insufficient (below 19%).<\/li>\n<li>In confined spaces (see\u00a0CATEC\u00a0) or in all areas with little or no ventilation: tanks, vats, silos, tunnels, ship holds, etc.<\/li>\n<li>If the contaminant concentration is unknown or immediately lethal to humans (IDLH).<\/li>\n<li>When the pollutant concentration is above the maximum allowable concentration or beyond the filter capacity.<\/li>\n<\/ul>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Filter cartridges for gas masks<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>There are three categories: Particle filters (dust, aerosols, bacteria, viruses), anti-gas filters (organic, inorganic gases and vapors, acids, etc.) and combined filters (gas and particles).<\/p>\n<\/div>\n<h3 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Particle filters<\/h3>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>Different particle filter classes:<\/p>\n<ul>\n<li>Class P1 filters: low efficiency, this stops at least 80% of the aerosol (i.e. less than 20% penetration)<\/li>\n<li>Class P2 filters: medium efficiency, this stops at least 94% of the aerosol (i.e. a penetration of less than 6%)<\/li>\n<li>P3 class filters (high efficiency): This stops at least 99.95% of the aerosol (i.e. less than 0.05% penetration)<\/li>\n<\/ul>\n<\/div>\n<h3 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Anti-gas filters<\/h3>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>There are different types of anti-gas filters depending on the nature of the gas or vapor. A marking consisting of a letter associated with a color indicates each filter type specific to each gas or gas family according to European standard EN14687. Similarly, for each gas or family of gases, there are three respiratory protection efficiency classes defined by EN143 and EN143\/A1 standards:<\/p>\n<p>Depending on the type of filtering device, the maximum permissible concentrations of toxic substances (gases or vapors) will be different, i.e. 50 x\u00a0OEL\u00a0for half masks and 2000 x OEL for full face masks. According to these parameters, the three efficiency classes of gas filters are:<\/p>\n<ul>\n<li>Class 1: Wafer filter (example A1 or ABEK1) \u2013 small capacity and low efficiency, gas content by volume below 0.1%.<\/li>\n<li>Class 2: Cartridge filter (example: A2B2 or ABEK2) \u2013 medium capacity, gas content by volume less than 0.5%.<\/li>\n<li>Class 3: For gas contents of less than 1% by volume.<\/li>\n<\/ul>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Combined anti-gas and particle filters<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>As the name suggests,\u00a0<strong>combined filters<\/strong>\u00a0It stops both gases and particles. The air first passes through the particle filter element (which also acts as a pre-filter) and then through the gas absorbing element (activated carbon). Their coding retains the same principle, a group of letters (for gases), a number (for efficiency class) and class level for particles: example ABEK2-P3.<\/p>\n<p>\u21d2 Find the right respiratory protection filter for your application<\/p>\n<\/div>\n<h2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\">Maintenance and annual control of masks<\/h2>\n<div data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\" data-was-processed=\"true\">\n<p>Respiratory protection masks are class 3 personal protective equipment. Therefore, like all class 3 PPE, they are subject to annual periodic inspection. This periodic check includes:<\/p>\n<ul>\n<li>Clean thoroughly with\u00a0water to remove any splashes (mud, saliva, etc.).<\/li>\n<li>For a more thorough clean, machine wash with a cleaning and disinfecting product<\/li>\n<li>High temperature drying<\/li>\n<li>Verification of pressure and leakage parameters on the control bench<\/li>\n<li>The mask should be individually bagged to ensure it is clean and healthy.<\/li>\n<\/ul>\n<p>GTC Industrial - Dr\u00e4ger's authorized maintenance center - carries out all annual periodic checks of Dr\u00e4ger respirators in our maintenance laboratory. Feel free to contact us for this class 3 PPE maintenance.<\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Gaz\u00a0maskesi ,\u00a0yar\u0131m maske\u00a0i\u00e7in EN140 standard\u0131na\u00a0ve\u00a0tam y\u00fcz maskesi\u00a0i\u00e7in EN136 standard\u0131na tabi olan ki\u015fisel koruyucu bir ekipmand\u0131r (PPE s\u0131n\u0131f 3) . En pop\u00fcler modeller,\u00a0esas olarak mevcut geni\u015f filtre yelpazesi nedeniyle 40 mm \u00fcniversal filtrelere sahip\u00a0tek kartu\u015flu DIN Rd40 versiyonlar\u0131d\u0131r (standart EN148-1).\u00a0\u00c7ift filtreli modeller,\u00a0rutin uygulamalar veya titiz \u00e7al\u0131\u015fmalar i\u00e7in tasarlananlardan daha kompakt, geni\u015f g\u00f6r\u00fc\u015f alan\u0131na ve daha iyi [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[39,40],"tags":[],"class_list":["post-804","post","type-post","status-publish","format-standard","hentry","category-3-ppe-sinifi","category-hava-temizleme-solunum-cihazlari"],"_links":{"self":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts\/804","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/comments?post=804"}],"version-history":[{"count":2,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts\/804\/revisions"}],"predecessor-version":[{"id":1101,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/posts\/804\/revisions\/1101"}],"wp:attachment":[{"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/media?parent=804"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/categories?post=804"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gazolcum.com\/en\/wp-json\/wp\/v2\/tags?post=804"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}